推进技术 ›› 2014, Vol. 35 ›› Issue (12): 1645-1652.

• 燃烧传热 • 上一篇    下一篇

横流马赫数对溢流孔附近流动及换热的影响 *

苏文超,朱惠人,聂建豪   

  1. 西北工业大学 动力与能源学院,陕西 西安 710072,西北工业大学 动力与能源学院,陕西 西安 710072,西北工业大学 动力与能源学院,陕西 西安 710072
  • 发布日期:2021-08-15
  • 作者简介:苏文超(1989—),男,硕士生,研究领域为航空发动机高温部件的传热与冷却技术。
  • 基金资助:
    国家重点基础研发发展计划(2013CB035702)。

Effects of Cross-Flow Mach Number on Flow and Heat Transfer Characteristics Around Effusion Hole

  1. School of Power and Energy,Northwestern Polytechnical University,Xi’an 710072,China,School of Power and Energy,Northwestern Polytechnical University,Xi’an 710072,China and School of Power and Energy,Northwestern Polytechnical University,Xi’an 710072,China
  • Published:2021-08-15

摘要: 为了研究冷气通道横流马赫数变化时溢流孔附近流动和换热情况,选取光滑冷却通道、90°溢流孔冷却通道和45°溢流孔冷却通道作为研究对象,保持入口雷诺数为8×104,在横流比分别为0.5和1的情况下,对横流马赫数为0.2和0.7时溢流孔附近流动及换热特性进行数值模拟。研究发现:在相同入口雷诺数和横流比条件下,横流马赫数由0.2增大为0.7时,溢流孔内的回流范围减小,孔内流动阻力变小,冷却通道壁面换热减弱。当横流比变化时,低横流比情况下横流马赫数对冷却通道壁面换热影响要更大。

关键词: 涡轮叶片;马赫数;溢流孔;冷却通道;横流比;换热系数;数值模拟

Abstract: Heat transfer and flow characteristics in a rectangular channel with 90° and 45° effusion hole under the cross-flow Mach number of 0.2 and 0.7 have been numerically studied. The entrance Reynolds number is 8×104 and cross-flow ratio is 0.5 and 1. A smooth channel was also investigated to get a reference for calculation. Numerical results reveal that when both the entrance Reynolds number and cross-flow ratio are constant,with an increase in cross-flow Mach number from 0.2 to 0.7,the range of inverse flow in the effusion hole is decreased and thus the flow resistance is weakened. Besides,the local heat transfer near the effusion holes is weakened with increase of the cross-flow Mach numbers. Additionally,the cross-flow Mach number,under the low cross-flow ratio,has a stronger effect on the heat transfer on cooling channel wall in comparison with the high cross-flow ratio.

Key words: Turbine blade;Mach number;Effusion hole;Cooling channel;Cross-flow ratio;Heat transfer coefficient;Numerical simulation