推进技术 ›› 2017, Vol. 38 ›› Issue (12): 2830-2835.

• 控制 测量 故障诊断 • 上一篇    下一篇

新型液氧/空气/异丁烷燃烧加热器研制及流场校测

杨 样1,晏至辉2,蒲旭阳2,曾令国1,马宏祥2   

  1. 中国空气动力研究与发展中心 超高速所,四川 绵阳 621000,中国空气动力研究与发展中心 高超中心,四川 绵阳 621000,中国空气动力研究与发展中心 高超中心,四川 绵阳 621000,中国空气动力研究与发展中心 超高速所,四川 绵阳 621000,中国空气动力研究与发展中心 高超中心,四川 绵阳 621000
  • 发布日期:2021-08-15
  • 作者简介:杨 样,男,博士,副研究员,研究领域为高焓风洞及高超声速试验技术。

A New Liquid-Oxygen/Air/Isobutane Combustion Heater Development and Flow Field Calibration

  1. Hypervelocity Aerodyanmics Institue,China Aerodynamics Research and Development Center, Mianyang 621000,China,Air-Breathing Hypersonic Technology Reasearch Center,China Aerodynamics Research and Development Center,Mianyang 621000,China,Air-Breathing Hypersonic Technology Reasearch Center,China Aerodynamics Research and Development Center,Mianyang 621000,China,Hypervelocity Aerodyanmics Institue,China Aerodynamics Research and Development Center, Mianyang 621000,China and Air-Breathing Hypersonic Technology Reasearch Center,China Aerodynamics Research and Development Center,Mianyang 621000,China
  • Published:2021-08-15

摘要: 为了发展高流场品质、安全可靠运行的高超声速高温风洞技术,研制了一种新型的液氧/空气/异丁烷燃烧加热器。该加热器采用“气液燃烧”模式组织燃烧,考虑了均匀流场设计,并利用空气-异丁烷火炬点火器实现点火。50kg/s量级燃烧加热器点火调试表明,主气流能实现快速点火,在火炬关闭后,继续维持稳定燃烧。利用Φ1m喷管,针对马赫数6,总压6.0MPa及5.2MPa开展流场校测,结果表明燃烧加热器在喷管出口直径80%的中心区域提供均匀气流,在流场均匀区内,马赫数均方根偏差在0.05以内,总温均方根偏差在20K以内,能支撑高超声速气动及推进试验。

关键词: 异丁烷;高温风洞;燃烧加热器;流场;校测

Abstract: In order to advance hypersonic high-temperature tunnel techniques which could provide high-quality flow field with safety and reliability,a liquid oxygen/air/isobutane combustion heater was developed. Combustion was realized by using ‘gas-oxidand and liquid-fuel combustion’ mode in this heater. A new air/isobutane igniter torch was used to ignite main airflow. And uniform-flow techniques were elaborately considered in designing the heater. A heater with mass flow rate of about 50kg/s was developed to perform ignition tests. These test results indicate that the heater can be promptly ignited and maintain stable combustion with low pressure fluctuation after the igniter was shut down. Moreover,flow field calibrations at a Mach number 6 and total pressure 6.0MPa and 5.2MPa were conducted with a nozzle of 1m diameter. The calibration results confirm that the heater could provide uniform flow within 80-percent central area at the nozzle exit. In this zone,the root mean square errors of Mach number and total temperature were within 0.05 and 20K,respectively. Therefore,the combustion heater can support hypersonic propulsion and aerodynamic experimental research effectively.

Key words: Isobutane;High-temperature tunnel;Combustion heater;Flow field;Calibration